BU-304b: Making Lithium-ion Safe

Battery packs using Li-ion require a mandatory protection circuit to assure safety under (almost) all circumstances. Governed by IEC 62133, the safety of Li-ion cell or packs begins by including some or all of the following safeguards.

  1. Built-in PTC (positive temperature coefficient) protects against current surges.
  2. CID (circuit interrupt device) opens the circuit at a cell pressure of 1,000kPa (145psi).
  3. Safety vent releases gases on excessive pressure buildup at 3,000kPa (450psi).
  4. Separator inhibits ion-flow by melting process when exceeding a certain temperature threshold(See BU-306: What is the Function of the Separator?)

The PTC and CID work well in a smaller 2- or 3-cell pack with serial and parallel configuration, however, these safety devices are often omitted in larger multi-cell batteries, such as those for power tools, because the shutdown can occur in a cascade format. (See BU-302: Series and Parallel Battery Configurations) While some cells may go offline early, the load current causes excess current on the remaining cells. Such overload condition could lead to a thermal runaway before the remaining safety devices activate.

In addition to internal cell safeguards, an external electronic protection circuit prevents any cell from exceeding 4.30V on charge. In addition, a fuse cuts the current if the skin temperature of any cell approaches 90°C (194°F). To prevent the battery from over-discharging, a control circuit cuts off the current path at about 2.20V/cell.

Each cell in a string needs independent voltage monitoring. The higher the cell count, the more complex the protection circuit becomes. Four cells in series had been the practical limit for consumer applications. Today, off-the-shelf chips also accommodate 5–7, 7–10 and 13 cells in series. For specialty applications, such as the hybrid or electric vehicle delivering several hundred volts, specialty protection circuits are made. Monitoring two or more cells in parallel to get higher current is less critical than controlling the voltage in a string configuration.

Protection circuits can only shield abuse from the outside, such as an electrical short or faulty charger. If, however, a defect occurs within the cell, such as a contamination of microscopic metal particles, the external protection circuit has little effect and cannot arrest the reaction. Reinforced and self-healing separators are being developed for cells used in electric powertrains, but this makes the batteries large and expensive.

Li-ion commonly discharges to 3.0V/cell. The lowest permitted “low-voltage” power cut-off is 2.5V/cell. It is not advised to keep the battery at that level as self-discharge could bring the cell to its cut-off voltage, causing the battery to go into sleep mode. Most chargers ignore Li-ion packs that have gone to sleep and a charge is no longer possible. (See BU-808a: How to Awaken Sleeping Li-ion)

In the ON position, the internal protection circuit has a resistance of 50–100mOhm, lower on power packs. The circuit typically consists of two switches connected in series; one is responsible for the high cut-off, and the other for the low cut-off. Larger packs need a more careful design than a smaller battery, and single cell packs for mobile phones and tablets get away with a voltage and current limit in addition to some intrinsic cell protection. (See BU-802a: How does Rising Internal Resistance affect Performance?)

Some low-cost consumer chargers may rely solely on the battery’s protection circuit to terminate the charge. Redundancy is paramount for safety, and unknowingly to the buyer, low-cost consumer chargers may be offered that do not have properly functioning charge algorithms. This could be a vehicular charger for a mobile phone or an e-cigarette.

A further concern arises if static electricity has destroyed the battery’s protection circuit. A shorted solid-state switch is permanently fused in the ON position without the user knowing. A battery with a faulty protection circuit functions normally but it fails to provide protection. The cell voltage could rise above a safe level and overcharge the battery. Heat buildup and bulging are early signs of malfunction, but some batteries explode without warning.

Low prices make products from Asia attractive, but safety standards my not be equal to those in branded products. A wise shopper spends a little more money and buys recognized brands. (See BU-810: What Everyone Should Know about Aftermarket Batteries)

Figure 1 shows batteries in equipment that disintegrated in a passenger aircraft before takeoff.

Li-ion exploded in cargo bay of an passenger aircraft
Figure 1: Li-ion exploded in cargo bay of an passenger aircraft [1]

Mishap by air traveler who checked in Li-ion batteries undeclared that exploded before take-off. Shipping of lithium-based batteries is regulated under UN 38.3.

Manufacturers of lithium-ion batteries do not mention the word “explosion” but refer to “venting with flame” or “rapid disassembly.” Although seen as a slower and more controlled process than explosion, venting with flame or rapid disassembly can nevertheless be violent and inflict injury to those in close proximity.

Simple Guidelines for Using Lithium-ion Batteries

  • Exercise caution when handling and testing lithium-ion batteries.
  • Do not short-circuit, overcharge, crush, drop, mutilate, penetrate with foreign objects, apply reverse polarity, expose to high temperature or disassemble packs and cells.
  • Use only lithium-ion cells with a designated protection circuit and approved charger.
  • Discontinue using the battery and/or charger if the pack temperature rises more than 10ºC (18ºF) on a regular charge.
  • The electrolyte is highly flammable and battery rupture can cause physical injury.
  • Use a foam extinguisher, CO2, dry chemical, powdered graphite, copper powder or soda (sodium carbonate) to extinguish a lithium-ion fire. Only pour water to prevent the fire from spreading.
  • If the fire of a burning lithium-ion battery cannot be extinguished, allow the pack to burn out on its own in a controlled and safe manner.

References

[1] Source: The Daily Telegraph; Sydney 23C-34C

Last Updated: 25-Oct-2021
Batteries In A Portable World
Batteries In A Portable World

The material on Battery University is based on the indispensable new 4th edition of "Batteries in a Portable World - A Handbook on Rechargeable Batteries for Non-Engineers" which is available for order through Amazon.com.

Comments

Comments are intended for "commenting," an open discussion amongst site visitors. Battery University monitors the comments and understands the importance of expressing perspectives and opinions in a shared forum. However, all communication must be done with the use of appropriate language and the avoidance of spam and discrimination.

If you have a suggestion or would like to report an error, please use the "contact us" form or email us at: BatteryU@cadex.com. We like to hear from you but we cannot answer all inquiries. We recommend posting your question in the comment sections for the Battery University Group (BUG) to share.

I understand. Hide this message.
Looking for comments from the previous website?

Comments from the previous website are not compatible with our new commenting system but we have preserved them so our users can still reference and make use the information in them.

Show Old Comments
On April 30, 2019, Daniel Yohannes wrote:
Is it possible to balance discharge two individual lithium ion batteries connected in parallel? Each battery contains 4cells connected in series.
On December 8, 2018, Mer wrote:
Hello would you pls give me data from lithium battery i mean therminal voltage ;current and so on
On December 4, 2018, KEN RHINEFRANK wrote:
Where are the answers to these questions?
On October 25, 2018, Mike Cummings wrote:
I understand the battery management systems, my confusion is I assumed the batteries had to be shipped completely off, but off is sleep mode and cell balancing is performed hourly even during shipping, is this safe?
On May 11, 2018, Cepi wrote:
In a Li-ion Battery pack should I fuse every used cell in both poles or only in the positive one? if in both, why?
On March 13, 2018, DHEERENDRA KUMAR wrote:
plz any body tell me how to make li ion battery over charge and under charge protection circuit using discrete component plz tell
On November 24, 2017, Sultan wrote:
I left my IPhone in one of my bags in my home for more than three years where the temperature vary from 5C to 58C ore more. Is this safe or shall I do more protection?
On October 11, 2017, Harry wrote:
What is the possibility of a normal lithium battery to explode.
On May 10, 2017, Joe wrote:
I dropped my cell phone into my home's well. It is an iPhone7, with a lithium battery, and the well is approximately 20' - 30' deep. What health hazards exist if I am not able to retrieve the phone and it sits at the bottom of my well for eternity? This well is the only water supply to my house. Thanks, Joe
On November 11, 2016, Elienay wrote:
Além dos riscos descritos acima... Posso usar um único circuito de proteção e juntar dois conjuntos de baterias em paralelo para aumentar o tempo de uso de meu celular... Bateria de ion litium