BU-501a: Discharge Characteristics of Li-ion

The early Li-ion battery was considered fragile and unsuitable for high loads. This has changed, and today lithium-based systems stand shoulder to shoulder with the robust nickel and lead chemistries. Two basic types of Li-ion have emerged: The Energy Cell and the Power Cell.

The performance of these two battery types is characterized by energy storage, also known as capacity, and current delivery, also known as loading or power. Energy and power characteristics are defined by particle size on the electrodes. Larger particles increase the surface area for maximum capacity and fine material decreases it for high power.

Decreasing particle size lowers the presence of electrolyte that fills the voids. The volume of electrolyte within the cell determines battery capacity. Decreasing the particle size reduces the voids between the particles, thereby lowering the electrolyte content. Too little electrolyte reduces ionic mobility and affects performance. Think of a drying felt pen that needs recuperating to keep marking papers.

Li-ion Energy Cell

The Li-ion Energy Cell is made for maximum capacity to provide long runtimes. The Panasonic NCR18650B Energy Cell (Figure 1) has high capacity but is less enduring when discharged at 2C. At the discharge cutoff of 3.0V/cell, the 2C discharge produces only about 2.3Ah rather than the specified 3.2Ah. This cell is ideal for portable computing and similar light duties.

Discharge characteristics of NCR18650B Energy Cell by Panasonic.
Figure 1: Discharge characteristics of NCR18650B Energy Cell by Panasonic [1]

The 3,200mAh Energy Cell is discharged at 0.2C, 0.5C, 1C and 2C. The circle at the 3.0V/cell line marks the end-of-discharge point at 2C.

Cold temperature losses:

  • 25°C (77°F) = 100%
  • 0°C (32°F) = ~83%
  • –10°C (14°F) = ~66%
  • –20°C (4°F) = ~53%

Li-ion Power Cell

The Panasonic UR18650RX Power Cell (Figure 2) has a moderate capacity but excellent load capabilities. A 10A (5C) discharge has minimal capacity loss at the 3.0V cutoff voltage. This cell works well for applications requiring heavy load current, such as power tools.

Discharge characteristics of UR18650RX Power Cell by Panasonic.
Figure 2: Discharge characteristics of UR18650RX Power Cell by Panasonic [1]

The 1950mAh Power Cell is discharged at 0.2C, 0.5C, 1C and 2C and 10A. All reach the 3.0V/cell cut-off line at about 2000mAh. The Power Cell has moderate capacity but delivers high current.

Cold temperature losses:

  • 25°C (77°F) = 100%
  • 0°C (32°F) = ~92%
  • –10°C (14°F) = ~85%
  • –20°C (4°F) = ~80%

The Li-ion Power Cell permits a continuous discharge of 10C. This means that an 18650 cell rated at 2,000mAh can provide a continuous load of 20A (30A with Li-phosphate). The superior performance is achieved in part by lowering the internal resistance and by optimizing the surface area of active cell materials. Low resistance enables high current flow with minimal temperature rise. Running at the maximum permissible discharge current, the Li-ion Power Cell heats to about 50ºC (122ºF); the temperature is limited to 60ºC (140ºF).

To meet the loading requirements, the pack designer can either use a Power Cell to meet the discharge C-rate requirement or go for the Energy Cell and oversize the pack. The Energy Cell holds about 50 percent more capacity than the Power Cell, but the loading must be reduced. This can be done by oversizing the pack, a method the Tesla EVs use. The battery achieves exceptional runtime but it gets expensive and heavy.

LiFePO4 Power Cell

Lithium iron phosphate (LiFePO4) is also available in the 18650 format offering high cycle life and superior loading performance, but low specific energy (capacity). Table 3 compares specifications of common lithium-based architectures. More information is on BU-205: Types of Lithium-ion.

Chemistry Nominal V Capacity Energy Cycle life Loading Note
Li-ion Energy 3.6V/cell 3,200mAh 11.5Wh ~1000 1C (light load only) Slow charge (<1C)
Li-ion Power 3.6V/cell 2,000mAh 7.2Wh ~1000 5C (continuous large load) Good temp. range
LiFePO4 3.3V/cell 1,200mAh 3.9Wh ~2000 25C (very large cont. load) Robust, safe
Table 3: Maximizing capacity, cycle life and loading with lithium-based battery architectures

Discharge Signature

One of the unique qualities of nickel- and lithium-based batteries is the ability to deliver continuous high power until the battery is exhausted; a fast electrochemical recovery makes it possible. Lead acid is slower and this can be compared to a drying felt pen that works for short markings on paper and then needs rest to replenish the ink. While the recovery is relatively fast on discharge, and this can be seen when cranking the engine, the slow chemical reaction becomes obvious when charging. This only gets worse with age.

A battery may discharge at a steady load of, say, 0.2C as in a flashlight, but many applications demand momentary loads at double and triple the battery’s C-rating. GSM (Global System for Mobile Communications) for a mobile phone is such an example (Figure 4). GSM loads the battery with up to 2A at a pulse rate of 577 micro-seconds (μs). This places a large demand on a small battery; however, with a high frequency, the battery begins to behave more like a large capacitor and the battery characteristics change.

GSM discharge pulses of a cellular phone
Figure 4: GSM discharge pulses of a cellular phone [2]
The 577 microsecond pulses drawn from the battery adjust to field strength and can reach 2 amperes.

In terms of longevity, a battery prefers moderate current at a constant discharge rather than a pulsed or momentary high load. Figure 5 demonstrates the decreasing capacity of a NiMH battery at different load conditions from a gentle 0.2C DC discharge, an analog discharge to a pulsed discharge. Most batteries follow a similar pattern in terms of load conditions, including Li-ion.

Cycle life of NiMH under different load conditions
Figure 5: Cycle life of NiMH under different load conditions [3]
NiMH performs best with DC and analog loads; digital loads lower the cycle life. Li-ion behaves similarly.

Figure 6 examines the number of full cycles a Li-ion Energy Cell can endure when discharged at different C-rates. At a 2C discharge, the battery exhibits far higher stress than at 1C, limiting the cycle count to about 450 before the capacity drops to half the level.

Cycle life of Li-ion Energy Cell at varying discharge levels
Figure 6: Cycle life of Li-ion Energy Cell at varying discharge levels [4]
The wear and tear of all batteries increases with higher loads. Power Cells are more robust than Energy Cells.

Simple Guidelines for Discharging Batteries

  • Heat increases battery performance but shortens life by a factor of two for every 10°C increase above 25–30°C (18°F above 77–86°F). Always keep the battery cool.
  • Prevent over-discharging. Cell reversal can cause an electrical short.
  • On high load and repetitive full discharges, reduce stress by using a larger battery.
  • A moderate DC discharge is better for a battery than pulse and heavy momentary loads.
  • A battery exhibits capacitor-like characteristics when discharging at high frequency. This allows higher peak currents than is possible with a DC load.
  • Nickel- and lithium-based batteries have a fast chemical reaction; lead acid is sluggish and requires a few seconds to recover between heavy loads.
  • All batteries suffer stress when stretched to maximum permissible tolerances.

References

[1] Source: Panasonic
[2] Courtesy of Cadex
[3] Source: Zhang (1998)
[4] Source: Choi et al (2002)

Last Updated: 11-Dec-2023
Batteries In A Portable World
Batteries In A Portable World

The material on Battery University is based on the indispensable new 4th edition of "Batteries in a Portable World - A Handbook on Rechargeable Batteries for Non-Engineers" which is available for order through Amazon.com.

Comments

Comments are intended for "commenting," an open discussion amongst site visitors. Battery University monitors the comments and understands the importance of expressing perspectives and opinions in a shared forum. However, all communication must be done with the use of appropriate language and the avoidance of spam and discrimination.

If you have a suggestion or would like to report an error, please use the "contact us" form or email us at: BatteryU@cadex.com. We like to hear from you but we cannot answer all inquiries. We recommend posting your question in the comment sections for the Battery University Group (BUG) to share.

I understand. Hide this message.
Looking for comments from the previous website?

Comments from the previous website are not compatible with our new commenting system but we have preserved them so our users can still reference and make use the information in them.

Show Old Comments
On August 29, 2019, Vikram Jain wrote:
Dear All, I was looking for instantaneous current calculation for Li-ion batteries with different chemistry. I want to calculate the pulse current w.r.t. SOC and Temperature along with this I would also like to keep in mind the electrical ratings of contactor and fuse. Can someone help me figure out how do i calculate pulse discharge current (not continuous) and how much overall time period I can allow in one complete discharge cycle ? Also the same calculations for Regen current during discharge ? Your help will be really appreciated a lot. Thank You Kind Regards Vikram Jain
On June 6, 2019, tom hoag wrote:
Can the remaining capacity of a lithium cell be determined by measuring the open circuit battery voltage? If not, how can the remaining capacity be determined?
On November 2, 2018, al wrote:
you discharged to 3 volts, not to 3,5.
On August 27, 2018, Nick wrote:
I and many others use lipo batteries in rc planes. Weight is at a premium. small highly stressed batteries are used, often discharging at an average rate of 15-20c. They not surprisingly have a short life, but received wisdom is that discharging cells below 3.0v will dramatically shorten life, so I don't. However I notice that a battery discharged to 3.0-3.1v will recover in a few seconds to around 3.5v when on no load. So, my question is - how close to the damage discharge level am I? have I really discharged it to 3.0v, or actually only to 3.5v?
On July 4, 2018, Laverna Botsford wrote:
Commonly the span transformation from plate into M-M, quantity traffic meter into yards, bodyweight conversions from gram to kilogram will be most widely utilised in mathematics and math areas and also one different Conversion Calculator also will involve the components like fever, rate, quantity, space, gasoline market, money etc.,.
On May 31, 2018, Hassan CHEAITO wrote:
could any one help me to find a method to calculate power density (W/Kg) basing on datasheet characteristics of battery where we find energy density (Wh/kg), C-rate, weight and so on .. Thanks for your help
On December 25, 2017, Shivam Baran wrote:
Best suitable lithium ion battery to charge lipo battery of 11.1Volt, 3S, 2200mah..(wirelessly)
On April 17, 2016, IqbalHamid wrote:
I am using TWO batteries attached to my laptop at the same time. I have noticed that Windows fuslly discharges the first battery before swtiching to the second battery. This is supposed to be bad according to this page as it can cause cell reversall and overdischarging. Do circuits in modern laptop batteries prevent this? Does anyone know of any software or utility which will allow me to set the point (discharge level) at which Windows will switch to using the second battery? Thanks.
On September 6, 2015, yadav wrote:
How much time can glows a 170volts bulb with the 240volts of li-ion battery
On August 31, 2015, Ranbir wrote:
How i an find out electromotive force series if zinc -0.76 v and lead -0.13 v. what would the emf of a cell be if the electrodes were lead and zinc
On August 27, 2015, Amit sinha wrote:
Hi , Nice work still few things I would like to explain . Consider the power factor of Not only UPS but also for batteries .example. 1000 va output will be 700 watts 700 watts/.85 = x ▶ invt eff. X/.65= Y▶ batt. Eff. Y/Vdc = Z ▶ vdc is no. Of batteries x volt of battery.ex 12 volt x 3 battery= 36 vdc So Z x (Backup time needed ) say 3 hrs So for example it comes 15 Multiply by 3 hrs So backup is 45 Ah HENCE , 3 BATTERIES ARE NEEDED FOR A 700 WATT LOAD ON A 3 BATTERY SYSTEM &#40;36 VDC&#41; for 3 hrs backup. Mail me at : amit@elnova.com www.elnova.com , Nice work still few things I would like to explain . Consider the power factor of Not only UPS but also for batteries .example. 1000 va output will be 700 watts 700 watts/.85 = x ▶ invt eff. X/.65= Y▶ batt. Eff. Y/Vdc = Z ▶ vdc is no. Of batteries x volt of battery.ex 12 volt x 3 battery= 36 vdc So Z x (Backup time needed ) say 3 hrs So for example it comes 15 Multiply by 3 hrs So backup is 45 Ah HENCE , 3 BATTERIES ARE NEEDED FOR A 700 WATT LOAD ON A 3 BATTERY SYSTEM &#40;36 VDC&#41; for 3 hrs backup. Mail me at : amit@elnova.com www.elnova.com
On April 18, 2015, Thomas wrote:
Dear Sir, I want to size the battery and its charger for a prime rated generator. I had tried it but not sure whether this correct or not. Kindly advice: Generator - 1250kVA prime Starting system data are as follows: Voltage for the battery = 24V Battery Charging Alternator - 24V-30Ah Starting Motor Capacity - 24V -7.5x2kW Maximum Allowable Resistance of Cranking Circuit - 1.5 m Ω Recommended Minimum Battery Capacity At 5゜C (41゜F) and above - 300Ah Below 5゜C (41゜F) through - 5゜C (23゜F) 600 Ah I had done the sizing in the following manner as per reference from Battery supplier webpage: Calculation Steps 1. Determine the current that the starter draws for the entire starting cycle. Here in our situation: The starter draws 16,000 amps rolling current, worst case. (During cranking, current drawn = I=V/R = 24V / (1.5 x 10 -3) = 24*1000/1.5 = 16,000Amps 2. The maximum cranking time per start attempt is 15 seconds, which equals 0.0042 of an hour (this was given in the website. dont know how did the supplier come about this value) 3. The maximum number of start attempts will be 5 (Same situation, this is being given in the webpage.) Note: My requirement is the battery must run for 24hours and charge within 21hours) 4. Ampere-hours (AH) drawn by the starter is = (16,000) x(0.0042) x(5) = 336 AH 5. It is require to charge the battery for 21hours. 6. The Recharge inefficiency constant for Lead acid battery = 1.4 7. Charger type required = Total AH drawn by starter x Recharge inefficiency constant / Desired recharge hours 8. Answer = 336 x 1.4 / 21 = 22.4 Amp charger is required. Thanks & best regards
On April 3, 2015, NC Malviya wrote:
Sir, I like to know, Inverter of 850 KVA with load 700W (app) installed with 150 Ah battery. If battery is fully charged, how much time it will last in normal time.
On February 28, 2015, Olga Palizo wrote:
How do I calculate to get the total lead in battery? I am doing the TIER II report. MSDS indicates 60% but how do I get the lbs? The battery is used on stand up riders Model # 118-D125-15 weight of battery is 2485
On February 3, 2015, TITTY VARGHESE wrote:
hi, I need some clarification of UPS battery run time calculation. The detail as follow: UPS Size : 10kVA Battery Voltage : 12V Battery Ah Rating: 100 Battery Qty: 32 Inverter Eff.: 93.5% I need to know what is the actual battery run time during the failure of main source? does the calculation load shall take on the total load of equipment or the ups rating 10kVA? Kindly please advise how to calculate and what is the best formula to used.
On January 15, 2015, Baragas wrote:
hi, I need some clarification of UPS battery run time calculation. The detail as follow: UPS Size : 10kVA Battery Voltage : 12V Battery Ah Rating: 100 Battery Qty: 32 Inverter Eff.: 93.5% I need to know what is the actual battery run time during the failure of main source? does the calculation load shall take on the total load of equipment or the ups rating 10kVA? Kindly please advise how to calculate and what is the best formula to used.
On October 11, 2014, klaus wrote:
what is 400 cca to amp / hr how to conbert as i have 4 x 12 volt lithium polymer batteries here in my home for a project but need to know the amp/hr on my batteries can you help?
On September 20, 2014, santosh wrote:
hello sir, i have 12v 150ah lead acid tubular battery, solar panel giving 4.5A/ hr and avg 6hrs is sunshine available. Load drawing around 20A/ day. battery charging through mppt controller of 30A rated. then, how much time required to fully charge my battery.
On August 17, 2014, Solid gold wrote:
A battery of 12v 40ah and 12v 80 ah in parallel , which battery would discharge first?
On June 26, 2014, Thomas Soares wrote:
A lead acid battery can be transformed to a non acid one. Remove the acid, clean several times with distiled hater and then fill with a solution of KAl(SO4)2 Potassium Alum. This kind of conversion will result in a new kind of energy source: 1) Less voltage; 2) Allows 100% discharge (even shot circuit) with no damage; 3) Fast recharge, but with pulsed DC; 4)Non toxic.
On May 31, 2014, Bob Sandor wrote:
What is the correct formula to determine how many hours I can draw .028 amps from a 12 volt 700 amp hour lead acid battery before the battery voltage drops to 11 volts?
On April 2, 2014, Dj wrote:
i Have 24 numbers of battery, each having 2V,600Ah connected in series with only 400 Watt load that means 48V of my system So can you help me how to calculate the back up time of this system.
On March 26, 2014, okugbesan ibrahim wrote:
how can i calculate 50%volt shutdown on a 24vdc/1400amps inverter batterry. NB: Inverter capacity is 30kva
On January 12, 2014, Anand patel wrote:
i want to know about the normal c20 and c10 rated battery and how to calculate, how much kWh(unit) can be obtained form particular battery like C10 26Ah dc12V battery how much kWh can be obtained at 12V and for C20 Rating Battery.
On November 15, 2013, vishal wrote:
Dear sir I have One 3.7V,600mAh Li-ion battery that battery have DoD is 27% but i want to DoD 70% above that. So what is Procedure for this any circuit have built or other..Please Suggest me. Give me process for improve battery DoD.
On October 31, 2013, LALIT wrote:
SIR PLEASE TELL ME HOW THE HRD END CRURRENT CALCULATE
On March 6, 2013, Slocket wrote:
Sorry correction, your example only 13 hours use * 50% = 6.5 hours as you discovered, I was using 20 hour run for 10 hours use. SLA rating is only for low current draw. Peukert charts are very much relevant. NiMH is twice that of SLA in rating for real world application using any kind of Medium to Heavy use draw. Medium use is >10% current rating of battery capacity. Low is less than 1<%. Your example of three 7aH batery for 21 Ah array pulling anything more than 2-3 Amps is going to cut your real amp hour capacity to 50% for SLA. You really need to buy 10x more battery or get NiMH --though NiMH self discharge over time quickly over several days in a solar array.
On March 6, 2013, Slocket wrote:
Zahid wrote: im using 12v 7.4Ah SLA battery x 3 pcs.. the load 19w 12v dc.. By calculation :- (12V x 7.2Ah )/ 19W = 4.5 hour x 3 pcs battery in parallel connection can i get 13 hour ?? but by actual run i got 5-7 hour only. i’m i using wrong battery or my calculation wrong.. ------------------------------------------------------ The Peukert effect. Your 7ah battery is too small. The rate in the above chart for 120Ah compared to you 7Ah*3=21Ah battery. Lead acid is 1.3 to 1.4. Your is 19w /12v = 1.58 Amp draw. 120/21 for battery in above chart *1.58 = proportional equivalent~ 9.0 amp so look the 9 amp and it gives capacity reduction of about 50% in the Peukert chart so you will get 20 hours run time down to 10 hours just from that, and even worst as your batteries age. SLA rating is only good for long slow discharge 20AH is 1 Amp for 20 Hours. Take 10x times (10Amps) that out in 2 Hours you get only roughly half to 1/3 that amount if your lucky. That is why my project ebike will have NiMH battery instead of SLA. The higher cost 5x is justified in lifetime use and performance. LiPo4 is still too much expense and funny picky charging/discharge/ quality.
On February 24, 2013, ashish wrote:
If possible, kindly share the info on making an SMPS charger of 4000 Watts and above
On February 11, 2013, Suresh Patil wrote:
If inverter efficiency is around 80%, current from 12 volts for 19W load is approx. 2 amps. When 3 batteries are in parallel, You have a 7.2 x 3 i.e.21.6AH (@ 20 Hr. rate.) Using Peukert equation calculation, you should get 8Hr. 30Min. approx. This makes the battery fully discharged. For better life, batteries are not discharged beyond 80%. So inverters' cut off volts are adjusted to higher value. Probably, the inverter efficiency may be even less than 80%. If you find exact current from the batteries, Peukert formula will give you quite accurate duration. There is no much complication.
On October 19, 2012, Ian wrote:
7Ah is the capacity at a rate that flattens the battery in 20 hours. Your load is much higher than that so you need to take the Peukert effect into consideration. SLA batteries have quite high Peukert effect. The Peukert calculation is much more complicated than what you have done, but you could use the top graph instead to make it easier.
On October 19, 2012, Zahid wrote:
im using 12v 7.4Ah SLA battery x 3 pcs.. the load 19w 12v dc.. By calculation :- (12V x 7.2Ah )/ 19W = 4.5 hour x 3 pcs battery in parallel connection can i get 13 hour ?? but by actual run i got 5-7 hour only. i'm i using wrong battery or my calculation wrong..
On August 30, 2012, Johnny wrote:
my cell battry is bulging , it's a li-ion, and i was wondering how i make it safe(er) to dispose of, can you help with that? the phone says "use authentic battery" so i'm afraid it might explode,
On July 24, 2012, Muhammad Ahmed wrote:
My Dear friends; I designed a solar system in which appliance load is 500 Watt and appliance watt per day is 1500. So I used 150watt 2 solar panel, 24volt and 12 A Solar charge controller, 2 batteries of 125Ah each. Normally 7 hours sunlight. My problem is that I want to calculate in how much time period batteries will again recharge. Please help me in this problem Thanks
On May 8, 2012, Syed wrote:
Hello, How do we calculate the no. of hours a battery can provide on continuous discharge of 250mA of capacity 1320mAh? Also providing the voltage the battery can provide after every hour of discharge of 250mA would be good. Note: Nominal voltage of the battery is 3.7V. max operating range is 2.75V to 4.2V. max continuous discharge current is 1000mA internal resistance is 150milli ohm Thanks
On May 8, 2012, Syed wrote:
Hello, How to calculate the charging and dischargin time of a Li- ion polymer battery of capacity 1230mAh, 3.7V applying 250mA constant current? Thank You
On February 24, 2012, Pier wrote:
How exactly do you define one cycle in a Li-Ion cell ? I find cycle count in Lenovo thinkpads but not sure as to how they compute it !!!
On February 23, 2012, Sheldon Patnett wrote:
Yes Peukert's Equation can be used for Lithium batteries. Their exponents are closer to 1.0 than lead acid Batteries.
On February 8, 2012, Komal wrote:
how to calculate the charging and discharging time of Li-ion battery with specification of 100 Ah, 12 V.and applying 2 A constant current.?????
On January 9, 2012, Terence Cheong wrote:
Please infrom me how to calculate the time for discharging a traction battery with 560Ah & 420
On November 25, 2011, TAHIR HUSSAIN wrote:
Dear Sir, I live in Pakistan and i am working in lead acid battery company. My question is, How can i calculate Peukert's number by theoretical or practical and each battery (size wise) has a different peukert number. Regards, TAHIR
On November 18, 2011, gary pione wrote:
thanks ian. i saw that on the second read thru. i have never been a good student
On November 18, 2011, Ian wrote:
You may have missed this, gary: "The Peukert Law of a battery is exponentialand the readings for lead acid are between 1.3 and 1.4. Nickel-based batteries have low numbers and lithium-ion is even better." Missing space in there. Different chemistries have different values. Soldering directly onto a Li-ion cell is not recommended. They can explode.
On November 18, 2011, gary pione wrote:
can anyone answer question number one from pier ? can peukerts equation be used for lithium type batteries?
On November 4, 2011, Pier wrote:
1) Can Peukert's constant be used across all battery chemistry's ? 2) Is there any equation where we can determine the remaining time in a battery upon knowing the discharge voltage during operation? 3) What exactly do you mean by efficiency of the battery ? 4) What is the effect of soldering on a Li-ion cell for paralleling by our self ?
On August 27, 2011, Ian wrote:
Peukart (title and sidebar menu) or Peukert (article)?
On June 20, 2011, CBT wrote:
Hi, Can somebody tell me how to model peukart law im modelling please? Thanks alot
On June 10, 2011, Gaurav wrote:
Is there any empirical formula to calculate battery DEPTH of Discharge for a given lifetime?
On June 7, 2011, Susanta Kumar Sahu wrote:
Dear Sir/Madam, I am Susanta Kumar Sahu to inform you that i have no knowledge about battery discharge (EX: 180AH battery, connecting with load that depends on customer how much it give back up like this ).Can you tell BACK UP concept of all bettery? Thank You. Susanta Kumar Sahu
On May 25, 2011, Samuel Maher Youssef wrote:
please i want to install solar system,and i will use flood deep cycle battery, i will use four battery 12 volt DC, can i use two battery each other 24 volt and what advantage to use 4 battery. thanks a lot.
On May 8, 2011, HITESH PATEL wrote:
battery full lod discharging chart